- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0001000000000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Bhethanabotla, Venkat R. (1)
-
Desrosiers, Jacob (1)
-
Li, Shuangming (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
& Attari, S. Z. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Heating of surface acoustic wave (SAW) devices can be utilized for micro-heating and in microreactor applications, but is a disadvantage in biosensing. In this contribution, we fabricate SAW devices in 128° YX LiNbO3 and ST X quartz substrates with same physical dimensions, having center frequencies approximately of 96 MHz and 78 MHz, respectively to study heating at several power levels. We demonstrate droplet heating is caused by acoustic wave streaming resulting from the coupling between fluid and solid. A 10 μm water droplet on a 128° YX LiNbO3 device can be heated up by 3.3 °C with 15 dbm power level, whereas, the ST X quartz device is only heated up by 0.7°C. Our work illustrates that the 128° YX LiNbO3 substrate shows great potential for liquid heating applications. The ST quartz substrate is better suited for removal of non-specifically bound (NSB) proteins in biosensing applications, especially if shear horizontal SAWs propagating in the orthogonal direction are utilized for biosensing.more » « less
An official website of the United States government
